The load testing anchor is used to verify bearing capacity of already installed anchorage points in lift shaft or machine room ceilings.

 

Instructions:

first, the chosen load testing anchor is fixed to the anchorage point with the above specified loop (1). Afterwards the applicable force has to be imposed (2) to break the material at the predetermined point. The on site attachments must be sufficiently dimensioned.If the test is positive, which means the anchor point resists the test, the working load of the anchor point is verified, taking into account the specified safety factors (predetermined breaking point).

 

Requirements:

The capacity of the anchorage point is verified if it passes the test. The load testing anchor cannot verify the capacity or the quality of the lift shaft or machine room ceiling itself not for the fixing of the anchorage point. The manufacturer is only liable for the load testing anchor itself.

 

The user and the company which mounted the parts carry the liability for the fixing of the anchorage point as well as the force transmission into the structural part.

1-1 of 1 results
Load testing anchor
20.50 € / Piece
plus VAT.
5 Variants